Meeting data quality objectives with interval information

Citation
Ck. Bayne et al., Meeting data quality objectives with interval information, ENV SCI TEC, 35(16), 2001, pp. 3350-3355
Citations number
21
Categorie Soggetti
Environment/Ecology,"Environmental Engineering & Energy
Journal title
ENVIRONMENTAL SCIENCE & TECHNOLOGY
ISSN journal
0013936X → ACNP
Volume
35
Issue
16
Year of publication
2001
Pages
3350 - 3355
Database
ISI
SICI code
0013-936X(20010815)35:16<3350:MDQOWI>2.0.ZU;2-T
Abstract
Immunoassay test kits are promising technologies for measuring analytes und er field conditions, Frequently, these field-test kits report the analyte c oncentrations as falling in an interval between minimum and maximum values. Many project managers use field-test kits only for screening purposes when characterizing waste sites because the results are presented as semiquanti tative intervals. However, field-test kits that report results as intervals can also be used to make project-related decisions in compliance with fals e-rejection and false-acceptance decision error rates established during a quantitative data quality objective process. Sampling and analysis plans ca n be developed that rely on field-test kits to meet certain data needs of s ite remediation projects.