A position-sensitive ionization chamber for thermal neutrons

Citation
B. Yu et al., A position-sensitive ionization chamber for thermal neutrons, IEEE NUCL S, 48(3), 2001, pp. 336-340
Citations number
6
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
ISSN journal
00189499 → ACNP
Volume
48
Issue
3
Year of publication
2001
Pages
336 - 340
Database
ISI
SICI code
0018-9499(200106)48:3<336:APICFT>2.0.ZU;2-1
Abstract
A position-sensitive neutron detector based on He-3 is being developed for a national crystal backscattering spectrometer (CBS) at a pulsed neutron so urce. It comprises a single gas volume, of constant depth, in the form of a n annulus that is also part of a truncated cone. Charge from each event is collected on one or two anode strips, out of a total 336 around the annulus , yielding an angular resolution of about 1 degrees. Low-noise signal proce ssing, in the form of a monolithic preamplifier/shaping amplifier connected to each anode strip, provides electronic noise that is small enough to per mit detector operation in ionization mode. In addition, the segmented anode s ensure near complete induced charge collection. This new detector therefo re has significant advantages over previous detectors used in CBS instrumen ts, which primarily consisted of arrays of individual He-3 filled cylindric al counters with dead regions and nonuniform detection efficiency. The opti mization of gas mixture/pressure, drift field, and shaping. time is signifi cant in achieving successful performance in the new detector.