Flow injection chemiluminescent analysis of isoniazid by direct hexacyanoferrate(III) oxidation

Citation
Ym. Huang et Zj. Zhang, Flow injection chemiluminescent analysis of isoniazid by direct hexacyanoferrate(III) oxidation, ANAL LETTER, 34(10), 2001, pp. 1703-1710
Citations number
11
Categorie Soggetti
Chemistry & Analysis","Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ANALYTICAL LETTERS
ISSN journal
00032719 → ACNP
Volume
34
Issue
10
Year of publication
2001
Pages
1703 - 1710
Database
ISI
SICI code
0003-2719(2001)34:10<1703:FICAOI>2.0.ZU;2-U
Abstract
A very simple chemiluminescence (CL) flow system is described for the deter mination of isoniazid based on its direct oxidation by hexacyanoferrate(III ) solution in an alkaline media. The system responds linearly to isoniazid concentration in the range 0.05-2 mug/mL with a detection limit (3 sigma) o f 0.01 mug/mL. Relative standard deviation (RSD) is 1.6% for 0.5 mug/mL of isoniazid (n=11). The system has been successfully applied to the determina tion of isoniazid in pharmaceutical preparations. The measurement could be performed in 30 s with sampling rate of 120 times per hour.