Determination of penconazole on personal protection equipment after field applications

Citation
M. Goumenou et K. Machera, Determination of penconazole on personal protection equipment after field applications, FRESEN J AN, 370(7), 2001, pp. 946-950
Citations number
15
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY
ISSN journal
09370633 → ACNP
Volume
370
Issue
7
Year of publication
2001
Pages
946 - 950
Database
ISI
SICI code
0937-0633(200108)370:7<946:DOPOPP>2.0.ZU;2-R
Abstract
A simple analytical method, validated in-house and infra-laboratory, has be en developed for the determination of penconazole on personal protection eq uipment (PPE) used by operators during field applications of Topas 20EW The analytical determination of penconazole was performed by GC-ECD. Sample pr eparation was based on a liquid extraction procedure. The possible effect o f different personal protection equipment matrices on the analytical determ ination of penconazole was studied and evaluated with regression analysis. No evidence of significant (at 95% CI level) effect was observed at several fortification levels. The percentage recovery of penconazole from the diff erent PPE was in the range 59-100% with adequate correlation with the level of fortification (r(2)>0.99). The RSD% was in the range of 1-15% and the L OD and LOQ for penconazole were 0.84 and 2.5 ng mL(-1), respectively.