Millimeter wave mixer with image recovery using dielectric resonators

Citation
Js. Jiang et al., Millimeter wave mixer with image recovery using dielectric resonators, J INF M W, 20(4), 2001, pp. 304-306
Citations number
3
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
JOURNAL OF INFRARED AND MILLIMETER WAVES
ISSN journal
10019014 → ACNP
Volume
20
Issue
4
Year of publication
2001
Pages
304 - 306
Database
ISI
SICI code
1001-9014(200108)20:4<304:MWMWIR>2.0.ZU;2-G
Abstract
The millimeter wave mixer with image recovery was presented. which used die lectric resonators at Ka-band as the band-rejection filter. The real circui t was also presented based on the theoretical analysis. The results show th at the signal conversion loss is reduced by about 1.1dB, and the image-to-s ignal conversion loss ratio is larger than 26dB by using the millimeter wav e mixer image recovery.