MARS - a project of the diffraction-limited fourth generation X-ray sourcebased on supermicrotron

Citation
Gn. Kulipanov et al., MARS - a project of the diffraction-limited fourth generation X-ray sourcebased on supermicrotron, NUCL INST A, 467, 2001, pp. 16-20
Citations number
10
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
467
Year of publication
2001
Part
1
Pages
16 - 20
Database
ISI
SICI code
0168-9002(20010721)467:<16:M-APOT>2.0.ZU;2-8
Abstract
The new approach for the fourth generation X-ray source-Multiturn Accelerat or-Recuperator Source (MARS)-was proposed recently. The installation consis ts of the radiofrequency (RF) multiturn accelerator (similar to the race-tr ack microtron) and long undulator(s). After passing through the undulator(s ) the electron beam is decelerated in the same RF accelerating structure. S uch energy recovery reduces dramatically the radiation hazard and decreases the required RF power. In this paper we present a more detail explanation of this scheme, and specify further the parameter limitations and requireme nts for the accelerator. (C) 2001 Elsevier Science B.V. All rights reserved .