Performance of a novel VUV bending magnet beamline

Citation
Yf. Song et al., Performance of a novel VUV bending magnet beamline, NUCL INST A, 467, 2001, pp. 569-572
Citations number
5
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
467
Year of publication
2001
Part
1
Pages
569 - 572
Database
ISI
SICI code
0168-9002(20010721)467:<569:POANVB>2.0.ZU;2-T
Abstract
A novel high resolution, high flux bending magnet beamline with an energy r ange from 5 to 40 eV has been constructed at SRRC. This Dragon-like beamlin e, which horizontally collects 50 mrad of synchrotron radiation from a bend ing magnet source, uses four cylindrical gratings with an included angle of 140 degrees and a movable curved exit slit. The average photon flux with a n energy resolving power of 1000 is about 2 x 10(12) photons/s, which is am ong the highest of all existing VUV bending magnet beamlines. An energy res olving power of 24 000 at 6.8 eV has been obtained from the Schumann-Runge bands (B-3 Sigma (-)(u) <-- X-3 <Sigma>(-)(g)) absorption spectra of O-2 ga s. A photon flux of 3 x 10(9) photons/s is measured at the energy resolving power of 24 000. This high flux bending magnet beamline offers excellent o pportunities for VUV experiments with a wide range spectrum. (C) 2001 Elsev ier Science B.V. All rights reserved.