Shortening of mandibular linear distance with multivector distraction

Citation
C. Aojanepong et al., Shortening of mandibular linear distance with multivector distraction, J CRANIOF S, 12(5), 2001, pp. 505-514
Citations number
4
Categorie Soggetti
Surgery
Journal title
JOURNAL OF CRANIOFACIAL SURGERY
ISSN journal
10492275 → ACNP
Volume
12
Issue
5
Year of publication
2001
Pages
505 - 514
Database
ISI
SICI code
1049-2275(200109)12:5<505:SOMLDW>2.0.ZU;2-N
Abstract
It was noted that when a multivector distractor is used, there is shortenin g of the linear distraction distance when the gonial angle is reduced and t he transverse distance is increased. The purpose of this study was to measu re the distance change at the mandibular corticotomy site when the gonial a ngle is reduced or the transverse distance is increased. The Synthes multiv ector distractor was used in this experiment. After initial linear distract ion, the distractor was activated by angular and transverse adjustments to achieve an angular, a transverse, and a combined angular and transverse reo rientation. The length of the pin from the distractor to the tip of pin was evaluated at 15, 20, and 25 mm. With the pins place at 180 degrees, the di stractor arm length was evaluated at 30, 35, 40, 45 and 50 mm apart, respec tively. The distance change between the ends of the pins was measured by me ans of a caliper. For angular activation, one turn shortened the linear dis traction distance at the pin end by 1.5 to 2.2 mm. For transverse activatio n, one turn shortened the linear distraction distance by 1.1 to 2 mm. For c ombined angular and transverse activation, one turn of angular activation p lus one turn of transverse activation shortened the linear distraction dist ance by 2.2 to 3.2 mm. For angular activation, increasing the pin length di d not alter the distance between the pin ends for any of the specific activ ations. Increase in the distractor arm length in angular reduction resulted in significant increase in the shortening. For transverse increase, altera tion in the distractor arm length resulted in the same shortening. Increase in the pin length resulted in increased shortening at the pin ends. When t he transverse and angular activation were combined, the shortening was 80% of the combined measurements. The distance between the pin ends will reflec t the distance between the bone segment at that site. It will be different at the outer cortex of the bone. These measurements will be valuable in pla nning the extent of additional linear distraction needed, when the angle is reduced or transverse distance is increased with the use of a multivector distractor. Alteration in the distractor arm length and pin length has a si gnificant effect on the extent of shortening.