K. Machida et al., Characteristics of crosstalk in the reproduced output of a newly developedmulti-channel MR head, J MAGN MAGN, 226, 2001, pp. 2054-2055
We prepared the multi-channel magnetoresistive head with a simple structura
l design and it has the advantages of high-density recording and ultra-high
transfer rate. Characteristics of crosstalk in the reproduced output of ou
r head have been estimated by a micromagnetic calculation using the Landau-
Lifshitz-Gilbert (LLG) equation, while the specimen head was fabricated and
evaluated. As a result, by applying a magnetic field of 40 Oe only between
adjacent channels, the crosstalk was much decreased without reducing the r
eproduced output. (C) 2001 Elsevier Science B.V. All rights reserved.