We present the results of a measurement of G made with a torsion-strip bala
nce used in two substantially independent ways. The two results agree to wi
thin their respective uncertainties; the correlation coefficient of the two
methods is -0.18. The result is G = 6.675 59(27) X 10(-11) m(3) kg(-1) s(-
2) with a standard uncertainty of 4.1 parts in 10(5). Our result is 2 parts
in 10(4) higher than the recent result of Gundlach and Merkowitz.