Reactor fission rate measurement for miniature neutron source reactor by solid state nuclear track detector

Citation
Yg. Li et al., Reactor fission rate measurement for miniature neutron source reactor by solid state nuclear track detector, RADIAT MEAS, 34(1-6), 2001, pp. 589-591
Citations number
3
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
RADIATION MEASUREMENTS
ISSN journal
13504487 → ACNP
Volume
34
Issue
1-6
Year of publication
2001
Pages
589 - 591
Database
ISI
SICI code
1350-4487(200106)34:1-6<589:RFRMFM>2.0.ZU;2-C
Abstract
The paper describes the reactor fission rate measurement principle and meth od by solid state nuclear track detection and gives the measurement result for miniature neutron source reactor. Finally, the reactor power is given i n combination with other reactor parameter. This method has advantage over other physics method and avoided the approximate suppose of some author in fission rate measurement. (C) 2001 Elsevier Science Ltd. All rights reserve d.