The present work is a continuation of a study of the influence of geometric
characteristics on the performance of reverse-flow cylindrical-conical cyc
lones. After studying the behavior of the pressure drop in previous work (A
rnosti et al., 1998), here performance in terms of collection efficiency in
the removal of particulate material is addressed. The independent variable
s considered in this study were inlet gas velocity (three velocities) and t
he following dimensions of the cyclone: the cylindrical section (three heig
hts) and internal height of the gas exit duct (three heights). The tests we
re performed using an 3(3) experimental design. Analysis of the results for
overall efficiency was carried out using response surfaces and the statist
ical parameters were estimated from linear regression.