POSSIBLE DIVERTOR SOLUTIONS FOR A FUSION-REACTOR .2. TECHNICAL ASPECTS OF A POSSIBLE DIVERTOR

Citation
P. Chappuis et al., POSSIBLE DIVERTOR SOLUTIONS FOR A FUSION-REACTOR .2. TECHNICAL ASPECTS OF A POSSIBLE DIVERTOR, Fusion engineering and design, 36(1), 1997, pp. 109-117
Citations number
24
Categorie Soggetti
Nuclear Sciences & Tecnology
ISSN journal
09203796
Volume
36
Issue
1
Year of publication
1997
Pages
109 - 117
Database
ISI
SICI code
0920-3796(1997)36:1<109:PDSFAF>2.0.ZU;2-7
Abstract
Safe operation of a fusion reactor divertor requires the exhaust of he at fluxes ranging from 5 to 30 MW m(-2). The different technical solut ions which are proposed rely on various water cooled copper hear sink designs. The protective armour may be Tungsten, Beryllium or Carbon de pending on the plasma interaction. Optimisation is achieved by an over all comparison stressing the compliance to industrial defects. Reliabl e designs have been proposed and tested on large elements with carbon tiles for several thousand cycles, at power levels up to 10 MW m(-2). (C) 1997 Elsevier Science S.A.