Vn. Danilov, CALCULATION OF THE ACOUSTIC CHANNEL OF A FLAW DETECTOR WITH DIRECT-ACTING ROUND TRANSDUCERS, Russian journal of nondestructive testing, 32(12), 1996, pp. 903-912
The model previously developed for calculating the characteristics of
elastic waves emitted by a laminar direct-acting transducer is used to
calculate echo signals for combined or separate similar transducers.
The calculation was done in the asymptotic approximation (of ray acous
tics) in the emission-reception far zone. Examples of the calculation
of the relative emf on the receiving transducer are given.