Intraoperative diffusion imaging on a 0.5 Tesla interventional scanner

Citation
Y. Mamata et al., Intraoperative diffusion imaging on a 0.5 Tesla interventional scanner, J MAGN R I, 13(1), 2001, pp. 115-119
Citations number
22
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging
Journal title
JOURNAL OF MAGNETIC RESONANCE IMAGING
ISSN journal
10531807 → ACNP
Volume
13
Issue
1
Year of publication
2001
Pages
115 - 119
Database
ISI
SICI code
1053-1807(200101)13:1<115:IDIOA0>2.0.ZU;2-#
Abstract
Intraoperative line scan diffusion imaging (LSDI) on a 0.5 Tesla interventi onal MRI was performed during neurosurgery in three patients. Diffusion tra ce images were obtained in acute ischemic cases. Scan time per slice was 46 seconds and 94 seconds, respectively, for diffusion tensor images. Diagnos is of acutely developed vascular occlusion was confirmed with follow-up sca ns. White matter tracts were displayed with the principal eigenvectors and provided guidance for the tumor surgery. In all cases, the diagnostic utili ty of LSDI was established. (C) 2001 Wiley-Liss, Inc.