Measurement of the lymphatic clearance of the human skin using a fluorescent tracer

Citation
Aj. Leu et al., Measurement of the lymphatic clearance of the human skin using a fluorescent tracer, J VASC RES, 38(5), 2001, pp. 423-431
Citations number
21
Categorie Soggetti
Cardiovascular & Respiratory Systems","Cardiovascular & Hematology Research
Journal title
JOURNAL OF VASCULAR RESEARCH
ISSN journal
10181172 → ACNP
Volume
38
Issue
5
Year of publication
2001
Pages
423 - 431
Database
ISI
SICI code
1018-1172(200109/10)38:5<423:MOTLCO>2.0.ZU;2-B
Abstract
The lymphatic clearance of the human skin at the instep of the foot was mea sured in 20 healthy volunteers (mean age +/- SD 33.8 +/- 10.5 years). Ten m icroliters of fluorescein isothiocyanate-dextran 150,000 were injected intr adermally and the fluorescent light intensity of the deposit was measured 1 0 min and 24 h after injection by window densitometry. Fluorescent light in tensity decreased by 31.2 +/- 13.5 arbitrary units (p < 0.0001) or by a fac tor of 4.1 +/- 3.9. Reproducibility was tested 2-6 weeks later in 7 subject s and an intraclass reliability of 0.76 was found. These are the first meas urements of the lymphatic clearance of the human skin using a fluorescent t racer. The method is easier and safer than the isotope clearance technique and small areas of the human skin can be investigated. The data found form a basis with which to compare measurements made in patients with different forms of edema. Copyright (C) 2001 S. Karger AG, Basel.