P. Niedzielski et al., Total content of arsenic, antimony and selenium in groundwater samples from western Poland, POL J ENV S, 10(5), 2001, pp. 347-350
This paper presents statistical analysis of results of determination of the
total content of arsenic, antimony, selenium and microcomponents in 49 sam
ples of groundwater from an area of western Poland (Wielkopolska). The tota
l content of arsenic reached up to 3.00 ng/ml, antimony 1.25 ng/ml, seleniu
m < 0.15 ng/ml, at detection limits of 0.16 ng/ml for As, 0.18 ng/ml for Sb
and 0.15 ng/ml for Se. The samples showed low values of the content of the
elements considered relative to the values obtained for water samples from
other regions. As the groundwater samples were collected from isolated wat
er bearing horizons, the values determined for them could be treated as geo
genic.