Electron cyclotron current start-up as a scheme to initiate ohmic disc
harges has been investigated with two circuits of open and shorted pri
mary windings of transformer. The experimental results indicate that w
e can achieve the saving of equivalent flux and the reduction of start
ing voltage in the initial phase for the two circuits in fundamental f
requency resonance region.