To suit to the management practices of the farmers of this region, an exper
iment was conducted to dewater effluent slurry from biogas plants by filter
ing its water content in a filtration chamber/unit or pit under lab and Wel
d conditions. Under lab conditions, the mesh having a hole size of 3 mm x 4
mm was found to be the best filtering net among all other meshes studied.
Dewatering in this mesh was studied in the filtration unit of 0.6 m(3) capa
city in the Weld and compared to a mesh of size 3.2 mm x 5.67 mm. It is fou
nd that the performance of 3 mm x 4 mm mesh was slightly better to dewater
slurry (6%) and for lesser TS content of filtered water. On an average, 27-
29% dewatering of slurry can be obtained from an effluent slurry having a T
S content of 93-94% and 13-14%. TS contents of the dewatered slurry can be
obtained with filtration unit that is suitable for transportation to the fa
rms or to storage.