SYRINGOSTOMY USING MYRINGOSTOMY TUBE - TECHNICAL NOTE

Citation
Ecg. Ventureyra et Ih. Tekkok, SYRINGOSTOMY USING MYRINGOSTOMY TUBE - TECHNICAL NOTE, Neurosurgery, 41(2), 1997, pp. 495-497
Citations number
9
Categorie Soggetti
Surgery,"Clinical Neurology
Journal title
ISSN journal
0148396X
Volume
41
Issue
2
Year of publication
1997
Pages
495 - 497
Database
ISI
SICI code
0148-396X(1997)41:2<495:SUMT-T>2.0.ZU;2-O
Abstract
OBJECTIVE: We describe the concept of a new syringostomy technique. ME THODS: The technique includes the insertion of a myringostomy tube thr ough a small myelotomy at the level of maximum enlargement of the syri nx. The inner diameter of the myringostomy tube is 1.14 mm. RESULTS: T his technique reduces the potential risks that are associated with oth er techniques that use bulky silastic catheters that are left inside t he spinal cord. CONCLUSION: We think that this technique is the least invasive of all similar techniques and that, in terms of drainage, the myringostomy tube is as efficient as commonly used silastic catheters .