R. Ferrarini et al., A preliminary comparison between nanofiltration and reverse osmosis membranes for grape juice treatment, J FOOD ENG, 50(2), 2001, pp. 113-116
Nanofiltration (NF) and reverse osmosis (RO) systems were compared using gr
ape juice as feed solution. The initial permeate flux (J) was 7.4, 8.1, and
1.7 dm(3) m(-2) h(-1) with NF membranes DS and DK, and RO membrane SWC, re
spectively. The exponential decay of J in the above NF and RO membranes was
characterized by a fouling index equal to 0.16, 0.22, and 0.24, respective
ly, The permeability of NF membrane DS doubled by increasing the working pr
essure from 32 to 45 bar. Despite the additional power (+30%) required to w
ork at the higher pressure value there was an energy saving per unit permea
te of approximately 35%. The working pressure and temperature affected the
selectivity of NF membranes. As expected, a direct relationship between mem
brane permeability and working temperature occurred; the permeate flux of N
F membrane DS increased by about 3% per degree of temperature rise. (C) 200
1 Elsevier Science Ltd. All rights reserved.