Up. Veera et al., Measurement of gas hold-up profiles in stirred tank reactors by gamma ray attenuation technique, CHEM ENG R, 79(A6), 2001, pp. 684-688
Gas hold-up is one of the most important hydrodynamic characteristics that
is needed for performance estimation, design and scale-up of reactors. The
performance of large-scale reactors can be reliably evaluated by measuring
the gas hold-up in such reactors. In the present work, local gas hold-up in
an industrial reactor has been measured with the help of gamma ray tomogra
phy. Based on these measurements, an empirical equation has been proposed f
or the estimation of the gas hold-up distribution. The proposed equation ha
s been validated by comparison with laboratory scale data.