B. Kabon et al., First experience with fiberoptically directed wire-guided endobronchial blockade in severe pulmonary bleeding in an emergency setting, CHEST, 120(4), 2001, pp. 1399-1402
Citations number
11
Categorie Soggetti
Cardiovascular & Respiratory Systems","Cardiovascular & Hematology Research
We report the first use of a new wire-guided endobronchial blocker in a cri
tical respiratory situation caused by localized pulmonary bleeding. During
emergency management, it became increasingly difficult to ventilate a multi
ple-trauma patient with a conventional single-lumen tube because of massive
bleeding through the bronchus of the left lower lobe. Using the Arndt endo
bronchial blocker set (William Cook Europe A/S; Bjaeverskor, Denmark), we w
ere able to prevent the spread of hemorrhaging and achieved effective venti
lation and marked improvement in gas exchange. This new device allows the e
ffective blockade of an isolated lobe under direct bronchoscopy to buy time
for further intervention.