EVALUATION OF BUILDING SEPARATION DISTANCE REQUIRED TO PREVENT POUNDING DURING STRONG EARTHQUAKES

Authors
Citation
J. Penzien, EVALUATION OF BUILDING SEPARATION DISTANCE REQUIRED TO PREVENT POUNDING DURING STRONG EARTHQUAKES, Earthquake engineering & structural dynamics, 26(8), 1997, pp. 849-858
Citations number
4
Categorie Soggetti
Engineering, Civil
ISSN journal
00988847
Volume
26
Issue
8
Year of publication
1997
Pages
849 - 858
Database
ISI
SICI code
0098-8847(1997)26:8<849:EOBSDR>2.0.ZU;2-6
Abstract
Presented herein is an analytical procedure for evaluating the separat ion distance required between two buildings to prevent pounding during strong earthquakes. The procedure is based on equivalent linearizatio n of non-linear hysteretic behaviour and application of the well-known CQC method of weighting normal mode responses, The numerical results obtained are compared with corresponding results obtained using the we ll-known SRSS and ABS methods. (C) 1997 by John Wiley & Sons, Ltd.