Sensitive LC determination of piroxicam after in vitro transdermal permeation studies

Citation
A. Doliwa et al., Sensitive LC determination of piroxicam after in vitro transdermal permeation studies, J PHARM B, 26(4), 2001, pp. 531-537
Citations number
23
Categorie Soggetti
Chemistry & Analysis
Journal title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
ISSN journal
07317085 → ACNP
Volume
26
Issue
4
Year of publication
2001
Pages
531 - 537
Database
ISI
SICI code
0731-7085(200111)26:4<531:SLDOPA>2.0.ZU;2-D
Abstract
A direct, very sensitive. simple and rapid high-performance liquid chromato graphic (HPLC) method for the determination of piroxicam, with tenoxicam as internal standard, has been developed and validated. Samples were chromato graphed on a 5 mum Scharlau C-18 column. The mobile phase was a mixture of acetonitrile-acetic acid 4% (pH 2.8) (45:55, v/v). Detection was at 354 run and the run time was 7 min. The limit of detection was 0.025 mug/ml. The d etector response was found to be linear in the concentration range 0.05-9 m ug/ml. This HPLC assay has been applied to measure the 'in vitro' percutane ous permeation of piroxicam through abdominal hairless rat skin, using Fran z-type diffusion cells, in order to obtain the concentration-time profiles of piroxicam. (C) 2001 Elsevier Science B.V. All rights reserved.