The anaesthetic management of a case of severe upper airways obstruction due to an enlarging subglottic benign polyp

Citation
B. Vadodaria et Cms. Cooper, The anaesthetic management of a case of severe upper airways obstruction due to an enlarging subglottic benign polyp, EUR J ANAES, 18(11), 2001, pp. 766-769
Citations number
2
Categorie Soggetti
Aneshtesia & Intensive Care
Journal title
EUROPEAN JOURNAL OF ANAESTHESIOLOGY
ISSN journal
02650215 → ACNP
Volume
18
Issue
11
Year of publication
2001
Pages
766 - 769
Database
ISI
SICI code
0265-0215(200111)18:11<766:TAMOAC>2.0.ZU;2-7
Abstract
The use of a newly developed aid to jet ventilation of the lungs, a modifie d Ben-Jet tube (The Hunsaker Monjet tube), is described in a patient with p artial upper airway obstruction. This report highlights an unusual use of t his device. The Monjet is a fluoroplastic, monitored, self-centring, fine b ore tube that can be inserted from the mouth through to the subglottic regi on. It was originally developed to anaesthetize healthy patients without ai rway obstruction who were undergoing suspension microlaryngoscopy.