Evaluation of electric-field uniformity in a reverberation chamber for radiated immunity testing

Citation
K. Harima et Y. Yamanaka, Evaluation of electric-field uniformity in a reverberation chamber for radiated immunity testing, IEICE TR CO, E84B(9), 2001, pp. 2618-2621
Citations number
11
Categorie Soggetti
Information Tecnology & Communication Systems
Journal title
IEICE TRANSACTIONS ON COMMUNICATIONS
ISSN journal
09168516 → ACNP
Volume
E84B
Issue
9
Year of publication
2001
Pages
2618 - 2621
Database
ISI
SICI code
0916-8516(200109)E84B:9<2618:EOEUIA>2.0.ZU;2-V
Abstract
In using a reverberation chamber for radiated immunity testing, it is impor tant to determine the number of discrete steps through which the stirrer ro tates and the number of probe locations for a given test volume in the cham ber. This is because they affect the uniformity and calibration of the fiel d in the test volume. We experimentally evaluated the effect of the numbers of stirrers and their steps on the field uniformity, and the effect of the number of probe locations on field calibration.