Impingement cooling in a rib-roughened channel with cross-flow

Citation
Rg. Jia et al., Impingement cooling in a rib-roughened channel with cross-flow, INT J N M H, 11(7), 2001, pp. 642-662
Citations number
16
Categorie Soggetti
Mechanical Engineering
Journal title
INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW
ISSN journal
09615539 → ACNP
Volume
11
Issue
7
Year of publication
2001
Pages
642 - 662
Database
ISI
SICI code
0961-5539(2001)11:7<642:ICIARC>2.0.ZU;2-C
Abstract
A numerical investigation to determine the velocity and heat transfer chara cteristics of multiple impinging slot jets in rib-roughened channels in the presence of cross-flow has been carried out Fluid flow is modeled using an explicit algebraic stress model A simple eddy diffusivity and a generalize d gradient diffusion hypothesis are applied for the modeling of turbulent h eat fluxes. The computations are validated against available experimental f luid flow and heat transfer data. Different size and arrangement of jets an d ribs are considered in detail while the Reynolds numbers of a jet and the channel inlet are fixed at 6,000 and 14,000, respectively. Results show th at the ratio (B/W) between the size of the jets and ribs is most important. An explanation is that the ribs inhibit the motion of eddies by preventing them from coming very close to the surface when B/W is low, e.g. B/W = 1, although the ribs will increase the turbulence intensity. This blockage lim ited the heat transfer enhancement effect of the ribs and impinging jets.