An alternative measurement method for magneto-impedance effect in amorphous alloys

Citation
F. Atalay et S. Atalay, An alternative measurement method for magneto-impedance effect in amorphous alloys, SENS ACTU-A, 94(1-2), 2001, pp. 39-43
Citations number
6
Categorie Soggetti
Instrumentation & Measurement
Journal title
SENSORS AND ACTUATORS A-PHYSICAL
ISSN journal
09244247 → ACNP
Volume
94
Issue
1-2
Year of publication
2001
Pages
39 - 43
Database
ISI
SICI code
0924-4247(20011031)94:1-2<39:AAMMFM>2.0.ZU;2-T
Abstract
An alternative measurement method for giant magneto-impedance (GMI) effect is described. The method measures pulse width instead of induced voltage be tween the ends of wire as a function of external applied field. In the meas urement method two ac signals are applied to the wire and it has been shown that by changing the amplitude of the low-frequency ac signal a large vari ation in the field dependence of pulse width can be obtained. (C) 2001 Else vier Science B.V. All rights reserved.