Use of hypercrosslinked polystyrene for the determination of pyrocatechol,resorcinol, and hydroquinone by reversed-phase HPLC with dynamic on-line preconcentration

Citation
Na. Penner et al., Use of hypercrosslinked polystyrene for the determination of pyrocatechol,resorcinol, and hydroquinone by reversed-phase HPLC with dynamic on-line preconcentration, J ANALYT CH, 56(10), 2001, pp. 934-939
Citations number
16
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
JOURNAL OF ANALYTICAL CHEMISTRY
ISSN journal
10619348 → ACNP
Volume
56
Issue
10
Year of publication
2001
Pages
934 - 939
Database
ISI
SICI code
1061-9348(200110)56:10<934:UOHPFT>2.0.ZU;2-D
Abstract
Adsorption isotherms of pyrocatechol, resorcinol, and hydroquinone on hyper crosslinked polystyrene MN-200 are described by the Langmuir equation; dist ribution coefficients of these compounds are 1500, 550, and 370 mL/g, respe ctively; breakthrough capacities are 15.3, 11.2, and 11.3 mg/g, respectivel y. The comparison of hypercrosslinked polystyrene with other sorbents in th e efficiency of the dynamic preconcentration of hydroxyphenols demonstrated its advantages. A procedure is proposed for the determination of pyrocatec hol, resorcinol, and hydroquinone in water by high-performance liquid chrom atography with dynamic on-line preconcentration on a concentrating column i nstead of the injector loop, which provides the determination of these comp ounds at concentrations down to 2-3 mug/L. The accuracy of the procedure wa s verified by the added-found method with a water sample.