Flow and heat transfer characteristics in the porous wick condenser of CPL

Citation
Y. Qu et al., Flow and heat transfer characteristics in the porous wick condenser of CPL, SCI CHINA E, 44(5), 2001, pp. 499-506
Citations number
6
Categorie Soggetti
Engineering Management /General
Journal title
SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES
ISSN journal
20950624 → ACNP
Volume
44
Issue
5
Year of publication
2001
Pages
499 - 506
Database
ISI
SICI code
2095-0624(200110)44:5<499:FAHTCI>2.0.ZU;2-N
Abstract
An analytical investigation has been conducted to understand the internal f luid flow and heat transfer in the condenser with porous wick of an innovat ive capillary pumping loop (CPL) system. A mathematical model is proposed a nd used to describe the:flow and heat transfer, especially interfacial tran sport phenomena. The liquid-vapor interface of the condensed liquid film wa s numerically determined. Some factors, such as vapor pressure, wall subcoo ling, wall heat load and thermofluid properties, have significant influence on the heat transfer process: and the shape of liquid-vapor interface. Mea nwhile, an experimental facility was setup and an experimental investigatio n was completed. Theoretical prediction and experimental results show quite good consistence.