Jc. Marin et al., Determination of G(12) by means of the off-axis tension test. Part II: a self-consistent approach to the application of correction factors, COMPOS P A, 33(1), 2002, pp. 101-111
Citations number
10
Categorie Soggetti
Material Science & Engineering
Journal title
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING
Several different tests and procedures have been proposed for the determina
tion of the intralaminar shear modulus G(12) in composite materials. The of
f-axis tension test, the +/-45 degrees test and the Iosipescu test are the
most widely used. The advantages of the off-axis test are the ease of speci
men preparation and the simplicity of the test procedure. A detailed review
of the most significant papers on the determination of G(12) by means of t
he off-axis test has been presented in Part I of the present study.
In this paper, a new graphical procedure, based on the numerical results fr
om a test with clamped end conditions, is introduced. The use of these grap
hs requires the use of clamping conditions in the tests. Thus, an experimen
tal study, using Moire interferometry, has been carried out to check the sa
tisfaction of this condition in the most commonly used methods of performin
g the test. It has been found that a specimen with bonded end tabs reproduc
es the most reliable clamped condition. Finally, the results of several 10
degrees off-axis tests on a graphite-epoxy composite are presented as a dem
onstration of the applicability of the correction scheme proposed in a wide
range of specimen aspect ratios. (C) 2001 Elsevier Science Ltd. All rights
reserved.