We describe a simple and secure technique for the insertion of a long Montg
omery type T-tube in patients with tracheal stenosis. An endotracheal tube
is placed into the lumen of the T-tube and by maintaining the airway during
insertion, the technique has been found to be safe and it can prevent the
kind of tracheal damage occurring with blind techniques. (C) 2001 Elsevier