Acoustic nonlinear parameter BIA describes the nonlinear features of the fi
nite amplitude sound wave propagation in a medium Compared with the lines p
arameters (such as sound velocity, attenuation coefficient etc.), this para
meter provides more information about the structure of the tissues. Therefo
re, the acoustic nonlinear parameter BIA may be a novel parameter for the u
ltrasound tissue characterization. In this paper, the nonlinear parameter B
IA computed tomography in reflection mode is proposed by using a compound t
ransducer. Theoretical analysis and experimental image of biological tissue
s, including porcine liver and hepatocirrhosis tissues are presented.