Automated flow-injection spectrophotometric determination of nitrosamines in solid food samples

Citation
E. Luque-perez et al., Automated flow-injection spectrophotometric determination of nitrosamines in solid food samples, FRESEN J AN, 371(6), 2001, pp. 891-895
Citations number
18
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY
ISSN journal
09370633 → ACNP
Volume
371
Issue
6
Year of publication
2001
Pages
891 - 895
Database
ISI
SICI code
0937-0633(200111)371:6<891:AFSDON>2.0.ZU;2-F
Abstract
A spectrophotometric method using a flow-injection system is proposed for t he determination of nitrosamines in foods (cured-meats). The method is base d on the photochemical cleavage of the N-NO bond of the nitrosamine to yiel d the corresponding amine and nitrite. The nitrite is then detected spectro photometrically, at 542 nm, by use of its reaction with a modified Griess r eagent. Different linear ranges between 0.8 and 2000 ng mL(-1) are obtained for the method, depending on the time of exposure of the sample to the UV radiation. The relative standard deviation varies between 2.0 and 3.9% and the sample throughput is between three and seven samples per hour, dependin g on the experimental conditions. The proposed method was successfully appl ied to the analysis of N-nitrosodimethylamine in cured ham and loin, bacon, and sausages.