Ya. Tygesen et al., Comparison of distortion and separation utilizing profile and Pow-R nickel-titanium rotary files, J ENDODONT, 27(12), 2001, pp. 762-764
The purpose of this study was to determine whether there was a difference i
n the frequency of file distortion and separation between nickel-titanium (
Ni-Ti) ProFile 0.04 ISO taper rotary files and Ni-Ti Pow-R 0.04 ISO taper r
otary files. For this study, 60 mesial root canals in 30 human mandibular f
irst molars were chosen with the curvature angle of the mesiobuccal and mes
iolingual canals of the same tooth within five degrees. ProFile and Pow-R f
iles were randomly assigned to either the mesiobuccal or mesiolingual canal
of the same tooth. Instrumentation proceeded per the manufacturer's recomm
endations, in a crown-down technique, using Gates Glidden burs and rotary f
iles in sizes #50 to #20. Positive and negative controls were used. The ins
truments were evaluated for signs of distortion or separation by three inde
pendent evaluators using magnification under microscope. A total of 420 fil
es were evaluated, 210 files for Pow-R and 210 files for ProFile. There was
no statistically significant difference in the incidence of instrument dis
tortion or separation between the two file systems that were studied.