M. Durcik et F. Havlik, EXPERIMENTAL-STUDY OF RADON AND THORON DIFFUSION THROUGH BARRIERS, Journal of radioanalytical and nuclear chemistry, 209(2), 1996, pp. 307-313
The radon chamber and radon calibration set have been modified for inv
estigation of the diffusion coefficients of the barriers for reduction
of radon exposure in the dwellings and for application as filters to
separate radon and thoron. The volume radon activities have been measu
red by continuous monitors with scintillation cell or ionisation chamb
er, The theory on which the experimental determination of a barrier di
ffusion coefficient is based, is presented. The diffusion ability of r
adon has been studied for different materials and the results of the m
easurements are presented and discussed.