Xy. Dong et al., Simultaneous displacement and temperature measurement with cantilever-based fiber Bragg grating sensor, OPT COMMUN, 192(3-6), 2001, pp. 213-217
Fiber Bragg grating (FBG) is demonstrated to measure displacement, which re
lies on attaching the FBG on a cantilever structure, so that the Vertical d
isplacement of the cantilever's free end can be obtained by measuring the w
avelength shift of FBG. A novel technique is then presented to measure disp
lacement and temperature simultaneously with a single FBG. The measured dis
placement and temperature sensitivities of this cantilever-based FBG sensor
are 8.22 x 10(-4) mm(-1) and 8.86 x 10(-5) (degreesC(-1)), respectively. A
nd the measurement range can be up to 10.5 mm. (C) 2001 Elsevier Science B.
V. All rights reserved.