M. Benfatto et S. Della Longa, Geometrical fitting of experimental XANES spectra by a full multiple-scattering procedure, J SYNCHROTR, 8, 2001, pp. 1087-1094
In this paper a new software procedure is presented, named MXAN, able to fi
t the XANES part (from the edge to about 200 eV) of experimental X-ray abso
rption data. The method is based on the fitting between the experimental sp
ectrum and several theoretical calculations generated by changing the relev
ant geometrical parameters of the site around the absorbing atom. The X-ray
photoabsorption cross section is calculated using the full multiple-scatte
ring scheme; different choices of the exchange correlation part of the pote
ntial can be utilised. To show the potentialities of the method the analysi
s of the nickel K-edge of the nickel ion in aqueous solution is presented.
The procedure is able to recover the correct information on the symmetry an
d atomic distances from the experimental Ni K-edge XANES spectrum. The reco
vered structure is found to be independent of the starting conditions, show
ing the theoretical uniqueness of the structural solution.