Analysis of trace level uranium in wastewater using the PIXE method

Citation
Y. Minagawa et al., Analysis of trace level uranium in wastewater using the PIXE method, NUCL INST B, 179(2), 2001, pp. 279-285
Citations number
14
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS
ISSN journal
0168583X → ACNP
Volume
179
Issue
2
Year of publication
2001
Pages
279 - 285
Database
ISI
SICI code
0168-583X(200107)179:2<279:AOTLUI>2.0.ZU;2-G
Abstract
Trace level uranium in wastewater is a particularly important issue for mat erial accountancy and radiation protection. It is difficult to detect trace level uranium without concentrating wastewater. This study is a discussion of particle-induced X-ray emission (PIXE) analysis that is used to find co ncentration of uranium easily. In the procedure discussed here, the quantit y of solution and backing material are examined to determine how they affec t the practicality of taking measurements. Our study resulted in findings t hat show higher sensitivity, shorter measurement time and wider range of co ncentration than those obtained by usual methods. (C) 2001 Elsevier Science B.V. All rights reserved.