Abstract
Changes of the surface state during the pretreatment of electroless nickel
plating on magnesium alloys were studied using the weight loss method, scan
ning election microscopy (SEM) and X-ray photoelectron spectroscopy (XPS).
The results showed that due to the formation of Mg(OH)(2) and MgF2 films on
the surface, alkaline cleaning and activating made little attack on the su
bstrate. Different etching solutions gave different etch rates and resultan
t morphologies. The CrOOH containing film, which was formed during etching
disappeared after activation.