Jd. Dickens et Cj. Norwood, Universal method to measure dynamic performance of vibration isolators under static load, J SOUND VIB, 244(4), 2001, pp. 685-696
A two-mass method is proposed to determine the four-pole parameters of a un
i-directional asymmetrical vibration isolator. It may be regarded as a univ
ersal testing procedure applicable to uni-directional or bi-directional, an
d asymmetrical or symmetrical vibration isolators under static load. Genera
lly, vibration isolators incorporating some form of active control are exam
ples of uni-directional asymmetrical vibration isolators. Experimental data
are presented that validate the two-mass method. (C) 2001 Academic Press.