R. Hellborg et al., Some examples of the application of an analitical technique to ion-opticalcalculations for a new injector of the Lund Pelletron accelerator, NUCL INST A, 465(2-3), 2001, pp. 297-305
The 3UDH Pelletron tandem accelerator in Lund is being developed to be more
suitable for accelerator mass spectrometry of heavy ions. This development
includes the installation of an electrostatic and a magnetic analyzer in a
new injector aimed to obtain better mass and energy separation. In the pre
sent paper some applications of the first-order analytical calculation tech
nique, used at the design stage of the new injector, are discussed. The est
imation of the maximum possible opening of the analyzer slits was carried o
ut, followed by the calculation of the analyzer acceptances. The values of
the acceptances for the two transversal planes, as well as their contours a
re given. Some results of more detailed numerical calculation of the ion be
am transport through the analyzers are reported. (C) 2001 Elsevier Science
B.V. All rights reserved.