Study of some optical glues for the Compact Muon Solenoid at the large hadron collider of CERN

Citation
M. Montecchi et Q. Ingram, Study of some optical glues for the Compact Muon Solenoid at the large hadron collider of CERN, NUCL INST A, 465(2-3), 2001, pp. 329-345
Citations number
20
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
465
Issue
2-3
Year of publication
2001
Pages
329 - 345
Database
ISI
SICI code
0168-9002(20010611)465:2-3<329:SOSOGF>2.0.ZU;2-X
Abstract
Two Avalanche Photodiodes will measure the light produced in each of the 61 ,200 PbWO4 crystals composing the barrel part of the electromagnetic calori meter of the Compact Muon Solenoid (CMS) at the Large Hadron Collider of CE RN. To improve the collection of the photons, these detectors will be glued to the crystal. To be used in CMS, the optical glue must fulfil several re quirements. This paper describes some of those requirements and reports the results of more general interest achieved during the investigation of seve ral commercial optical glues. In particular, refractive index, absorption l ength, radiation hardness and forecast ageing after 15 years are reported. The most promising glue for CMS was more deeply investigated; its chemical composition and a method to measure the curing time in realistic conditions are reported. (C) 2001 Elsevier Science B.V. All rights reserved.