Ch. Kang et al., Hysteresis behavior of CFT column to H-beam connections with external T-stiffeners and penetrated elements, ENG STRUCT, 23(9), 2001, pp. 1194-1201
This paper is a study on concrete-filled tubular (CFT) column to H-beam wel
ded connections that are reinforced externally with T-shaped stiffeners at
the junction of the column and beam, and with a reinforcing bar or bent pla
te which penetrates a column. Cyclic loading tests on eight cruciform conne
ctions and finite clement analysis using ABAQUS were carried out. The resul
ts of the tests demonstrate that an increased stiffener length was more eff
ective than an increase in the area of penetrated elements for the criteria
of both strength and stiffness. Also, good agreements between analytical r
esults and experimental tests are found. By reinforcing external T-stiffene
rs, the connection moments of all specimens exceed the beam full plastic mo
ment and stable hysteresis behavior under cyclic loading is shown. (C) 2001
Elsevier Science Ltd. All rights reserved.