Shunt impedance and power of the BEPC DC separator

Citation
Jp. Dai et al., Shunt impedance and power of the BEPC DC separator, HIGH EN P N, 25(7), 2001, pp. 680-683
Citations number
4
Categorie Soggetti
Physics
Journal title
HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION
ISSN journal
02543052 → ACNP
Volume
25
Issue
7
Year of publication
2001
Pages
680 - 683
Database
ISI
SICI code
0254-3052(200107)25:7<680:SIAPOT>2.0.ZU;2-Y
Abstract
During the operation of BEPC, the cable isolation layer near the high volta ge connector of the DC separator is often melted, which is probably caused by the power of the resonant modes. This paper presents the measurement of the shunt impedance and the calculation of the power dissipated in the sepa rator and through the connector.