EFFECT OF HELIUM IMPLANTATION ON TENSILE PROPERTIES OF V-TI-CR-SI TYPE ALLOY

Citation
M. Satou et al., EFFECT OF HELIUM IMPLANTATION ON TENSILE PROPERTIES OF V-TI-CR-SI TYPE ALLOY, Science Reports of the Research Institutes, Tohoku University, Series A: Physics, Chemistry, and Metallurgy, 45(1), 1997, pp. 157-161
Citations number
6
Categorie Soggetti
Material Science","Metallurgy & Metallurigical Engineering
ISSN journal
00408808
Volume
45
Issue
1
Year of publication
1997
Pages
157 - 161
Database
ISI
SICI code
0040-8808(1997)45:1<157:EOHIOT>2.0.ZU;2-O
Abstract
Helium implantation of 50at.ppmHe by cyclotron accelerator was adopted to study helium effect on tensile properties of the V-5Ti-5Cr-1Si-Al- Y type alloy. Tensile tests were conducted at temperatures ranging fro m room temperature to 850 degrees C with strain rates from 6.7x10(-5) to 6.7x10(-3)/s. Increase of yield stress was not appreciable in heliu m-implanted specimens except for 450 degrees C. Intergranular fracture mode was observed specimens tested at temperatures above 450 degrees C. Decrease of elongation was observed at all testing temperatures. Re lationship,between tensile strength and decrease of elongation was dis cussed.