DETERMINATION OF THE OPTICAL PURITY FOR SERINE AND THREONINE BY GAS-CHROMATOGRAPHY ON A CHIRAL COLUMN

Citation
B. Fransson et U. Ragnarsson, DETERMINATION OF THE OPTICAL PURITY FOR SERINE AND THREONINE BY GAS-CHROMATOGRAPHY ON A CHIRAL COLUMN, Chemistry Letters, (8), 1997, pp. 779-780
Citations number
9
Categorie Soggetti
Chemistry
Journal title
ISSN journal
03667022
Issue
8
Year of publication
1997
Pages
779 - 780
Database
ISI
SICI code
0366-7022(1997):8<779:DOTOPF>2.0.ZU;2-E
Abstract
In a two-step procedure, serine and threonine were converted first to N-isobutoxycarbonyl-amino acid 2,2,2-trifluoroethyl esters and subsequ ently also to novel N,O-bis-isobutoxycarbonyl-derivatives. As such all four isomers of threonine could easily be resolved on a commercial ch iral (Chirasil-D-Val) gas chromatography column at 140 degrees C. A si gnificant influence of the configuration at the beta-position on the r etention time was thereby observed. Similarly, improved separation was demonstrated for the two enantiomers of N,O-bis-isobutoxycarbonyl-ser ine isobutylamide.