DOUBLE-WAVELENGTH SUPERHETERODYNE INTERFEROMETER FOR ABSOLUTE RANGINGWITH SUBMILLIMETER RESOLUTION - RESULTS OBTAINED WITH A DEMONSTRATIONMODEL BY USE OF ROUGH AND REFLECTIVE TARGETS

Citation
G. Margheri et al., DOUBLE-WAVELENGTH SUPERHETERODYNE INTERFEROMETER FOR ABSOLUTE RANGINGWITH SUBMILLIMETER RESOLUTION - RESULTS OBTAINED WITH A DEMONSTRATIONMODEL BY USE OF ROUGH AND REFLECTIVE TARGETS, Applied optics, 36(25), 1997, pp. 6211-6216
Citations number
14
Categorie Soggetti
Optics
Journal title
ISSN journal
00036935
Volume
36
Issue
25
Year of publication
1997
Pages
6211 - 6216
Database
ISI
SICI code
0003-6935(1997)36:25<6211:DSIFAR>2.0.ZU;2-I
Abstract
The potential of double-wavelength interferometry is well known, espec ially regarding the capability of performing absolute distance measure ments of rough targets with high resolutions. We describe the experime ntal results obtained with a demonstration model of a double-wavelengt h interferometer with superheterodyne detection. Our system, implement ed with two four-quadrant detectors to improve the detection probabili ty, has,demonstrated the ability to reach resolutions of 0.2 mm at 5-m distances on rough targets in 50-ms integration time. (C) 1997 Optica l Society of America.