Y. Inoue et al., OBSERVATION OF LIGHT FROM RESISTIVE PLATE CHAMBERS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 394(1-2), 1997, pp. 65-73
Electrically induced signals and light emissions from Restrictive Plat
e Chamber (RPC) are simultaneously measured using a glass RPC with tra
nsparent high-voltage planes, operating in the streamer mode. With one
exception, good correspondence is seen in between the electrical and
optical signals in every aspect: signal shapes, pulse heights, timing
and afterpulses. The one exception is a possible limiting effect obser
ved on the optical signal pulse height for a given pulse height of ele
ctrically induced signal. Shapes of the signal visually observed by ey
e are also described.